How to solve Naviswoks Network License unable to get from network in VPN connection?

If your user from remote site office report you that they cannot user their Navisworks with VPN connection and faced with below error, you can settle with the solution mentioned in following.

"A valid license could not be obtained by the network license manager.

Error [1.5.-15]"

"A valid license could not be obtained by the network license manager.

Error [1.5.-18]"

1) Right-click My Computer. Click Properties.
(for Vista and Windows 7, click the "Advanced system settings" link.)
2) In the System Properties dialog box, click the Advanced tab.
3) On the Advanced tab, click Environment Variables.
4) In the Environment Variables dialog box, under System Variables, click New.
5) In the New User Variable dialog box, enter FLEXLM_TIMEOUT for the name and 10000000 for the value.
6) Click OK to close each dialog box.
7) Launch the Navisworks application.


If you are able to obtain a license, the value of 1000000 microseconds (1 second) is sufficient. If you still cannot obtain a license, repeat the procedure; increasing the value in 1000000 microsecond increments until you are able to obtain a license from the license server.

Although I only talk about Navisworks in this post, you still can use above solution method for other Autodesk Application as well.


May you all be happy.
(Be knowledgeable, pass it on then)

Comments

Popular posts from this blog

Fortigate guide for Begineer - 6

I would like to explaine how to troubleshoot the Fortigate Unit configured by Transparent Mode in step by step this time. Let's assume, you have one Fortigate Unit that configured as Transparent Mode. But devices from Internal/Private Network unable to access Internet/Public Network through your Fortigate Unit. OK. Let's troubleshoot with following steps, 1) Check the physical network connections between the network and the FortiGate unit, and between the FortiGate unit and the Internet. 2) Check the router and ISP-supplied equipment to make sure it is operating correctly. 3) Verify that you can connect to the internal interface by connecting to the management IP address of the FortiGate unit from the Internal network. From the internal network, attempt to ping the management IP address. If you cannot connect to the internal interface, verify the IP configuration of the PC and make sure the cables are connected and all switches and other devices on the network are powered on a...

Why do we need network virtualization?

We need to think about Server Virtualization first if we want to talk about Network Virtualization. In the era of cloud computing, servers are virtualized and used in Data Centers. We are facing a lot of problem when we virtualized our Servers, 1) Routing and Switching Problem Routing become the issue when we create Virtual Switch and VLANs according to production requirement. Network Team might need some time to change on their end to meet with Server Virtualization Team changes on their end. ၂) Firewall Services Physical Firewall are difficult to manage due to the large number of rules needed to satisfy business requirements. New applications, new projects, and new networks all come with potential security requirements, which impact centralized firewall management. ၃) Load Balancing Let's say your company deploys a new physical load balancer for each tenant, resulting in increased capital expenditures. Once a tenant reaches their maximum capacity, it ca...

Solving "WSUS administration console was unable to connect to the WSUS Server via the remote API" error

Today, I've got below when I try to connect my WSUS Server via WSUS Console. Below logs are display in Event Logs too. The WSUS administration console was unable to connect to the WSUS Server via the remote API.  Verify that the Update Services service, IIS and SQL are running on the server. If the problem persists, try restarting IIS, SQL, and the Update Services Service. The WSUS administration console was unable to connect to the WSUS Server via the remote API. Verify that the Update Services service, IIS and SQL are running on the server. If the problem persists, try restarting IIS, SQL, and the Update Services Service. System.Net.Sockets.SocketException -- No connection could be made because the target machine actively refused it 172.16.99.98:80 Source System Stack Trace:    at System.Net.Sockets.Socket.DoConnect(EndPoint endPointSnapshot, SocketAddress socketAddress)    at System.Net.ServicePoint.ConnectSocketInternal(Boolean connectFailure, Soc...